Address
uae - Dubai
Phone number
+971 50 8424 118

Hydraulic diaphragm metering pump Hydro/ 3 API 675

Price: 1$

For accurate information and price inquiries, please contact us. We are happy to answer your questions and meet your needs.

contact us

We will respond to you as soon as possible.

Available on backorder

Hydraulic Diaphragm Metering Pump HYDRO API

Capacity range of single-head pump: 7 – 1,506 l/h, 100 – 7 bar

The HYDRO API 675 is an extremely robust hydraulic diaphragm metering pump, which meets the most exacting safety requirements and is designed in accordance with API 675. This is ensured by the PTFE multi-layer diaphragm with diaphragm monitoring, the full-motion drive and automatic bleeding, for example. Its modular construction makes it extremely versatile.

Technical Details

  • Stroke length: 15 mm (HA1a, HA2a, HA3a), 20 mm (HA4a)
  • Rod force: 2000 N (HA1a, HA2a), 4200 N (HA3a), 5800 N (HA4a)
  • Stroke volume adjustment range: 0 – 100%
  • Stroke volume adjustment: manually using scaled rotary dial (with electric actuator or control drive as an option).
  • Metering reproducibility is better than ± 1% in the 10 – 100% stroke volume range under defined conditions and with correct installation
  • PTFE multi-layer diaphragm with electrical diaphragm monitoring with condition signals sent via contact
  • Integrated hydraulic relief and bleed valve
  • Full-motion drive
  • Wetted materials: PVDF, PTFE+25% carbon, stainless steel 1.4571, Hastelloy C.
  • A wide range of drive versions is available: Three-phase or standard three-phase motors or motors for use in areas at risk from explosion, different flange designs for use of customer-specific motors
  • Degree of protection: IP 55
  • Design in compliance with API 675

Hydraulic Diaphragm Metering Pump HYDRO HA1a

Technical data for HYDRO HA1a (50 Hz)

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
60125150187214
mmbarl/hl/hl/hl/hl/hml/strokem WCG-DNkg
* Double ball valve with female thread
9100[0.8][1.5][1.9][2.5][3.0]0.93.0NPT 1/4 – DN 3 *31
964(1.3) – 1.3(2.9) – 2.9(3.1) – 3.1(4.0) – 4.8(4.8) – 5.30.93.0NPT 1/4 – DN 3 *31
940(1.7) – 1.8(2.7) – 3.9(3.6) – 4.7(4.0) – 6.0(5.5) – 6.80.93.0NPT 1/4 – DN 3 *31
925(1.7) – 2.1(2.8) – 4.5(3.8) – 5.6(4.6) – 7.0(5.5) – 8.00.93.0NPT 1/4 – DN 3 *31
910(1.7) – 2.5(2.8) – 5.2(3.8) – 6.3(4.6) – 7.8(5.5) – 9.10.93.0NPT 1/4 – DN 3 *31
12100(2.9) – 2.9(5.5) – 6.0(7.4) – 7.4(8.0) – 9.3(9.0) – 10.11.73.0NPT 1/4 – DN 6 *31
1264(2.8) – 3.6(4.5) – 7.7(7.0) – 9.1(8.0) – 11.4(9.0) – 13.01.73.0NPT 1/4 – DN 6 *31
1240(2.5) – 4.1(4.5) – 8.7(6.0) – 10.4(7.0) – 13.0(9.0) – 14.71.73.0NPT 1/4 – DN 6 *31
1225(2.3) – 4.5(4.8) – 9.4(6.0) – 11.1(7.0) – 13.8(9.0) – 15.91.73.0NPT 1/4 – DN 6 *31
1210(2.5) – 4.8(4.8) – 10.1(6.0) – 12.1(7.0) – 15.1(9.0) – 17.11.73.0NPT 1/4 – DN 6 *31

Technical data for HYDRO HA1a (60 Hz)

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
5972149180224
mmbarl/hl/hl/hl/hl/hml/strokem WCG-DNkg
* Double ball valve with female thread
9100[0.5][0.8][1.8][2.0][3.0]0.93.0NPT 1/4 – DN 3 *31
964[1.2](1.6) – 1.6(3.3) – 3.3(3.7) – 3.7(4.8) – 5.70.93.0NPT 1/4 – DN 3 *31
940(1.7) – 1.7(2.0) – 2.1(3.2) – 4.6(4.3) – 5.6(4.8) – 7.20.93.0NPT 1/4 – DN 3 *31
925(2.0) – 2.1(2.0) – 2.5(3.4) – 5.4(4.5) – 6.7(5.5) – 8.40.93.0NPT 1/4 – DN 3 *31
910(2.0) – 2.5(2.0) – 3.0(3.4) – 6.2(4.5) – 7.5(5.5) – 9.30.93.0NPT 1/4 – DN 3 *31
12100(2.8) – 2.8(3.5) – 3.5(6.6) – 7.2(8.8) – 8.8(9.6) – 11.11.73.0NPT 1/4 – DN 6 *31
1264(2.4) – 3.6(3.4) – 4.3(5.4) – 9.2(8.4) – 10.9(9.6) – 13.61.73.0NPT 1/4 – DN 6 *31
1240(2.6) – 4.0(3.0) – 4.9(5.4) – 10.4(7.2) – 12.4(8.4) – 15.61.73.0NPT 1/4 – DN 6 *31
1225(2.6) – 4.4(3.0) – 5.4(5.7) – 11.2(7.2) – 13.3(8.4) – 16.51.73.0NPT 1/4 – DN 6 *31
1210(2.6) – 4.4(3.0) – 5.7(5.7) – 12.1(7.2) – 14.5(8.4) – 18.11.73.0NPT 1/4 – DN 6 *31

Piston Ø 9 and 12, version with double ball valves.

The permitted rated flow configuration is possible in the stated range when pumps are selected in accordance with API 675 (control range 1:10).

The litre capacity indicated using […] is the maximum litre capacity with an applicable control range of 1:5 and does not therefore satisfy API 675.

Example: a 12 mm piston, 40 bar pressure and stroke rate of 125 strokes/min results in (4.5) – 8.7, i.e. the control range of 1:10 is met for a rated flow of between 4.5 l/h and 8.7 l/h.

Wetted materials for HYDRO HA1a

Identity code of materialDosing headSuction/discharge connectionSeals/ball seatBalls
S1Stainless steel 1.4571/1.4404Stainless steel 1.4581PTFE/stainless steel 1.4404Ceramic

Motor data for HYDRO HA1a

Identity code specificationPower supplyRemarks
S3-phase, IP 55*230 V/400 V50 Hz0.37 kW
T3-phase, IP 55*230 V/400 V
265 V/460 V
50 Hz
60 Hz
0.37 kWWith PTC, speed control range 1:5
R3-phase, IP 55*230 V/400 V50 Hz0.37 kWWith PTC, speed control range 1:20, with external fan 1-phase 230 V; 50/60 Hz
V1-phase, IP 55*230 V50 Hz0.37 kWVariable speed stroke control motor with integrated frequency converter
L3-phase, II 2G Ex de IIC T4 Gb230 V/400 V50 Hz0.37 kWWith PTC, speed control range 1:5
Q3-phase, II 2G Ex de IIC T4265 V/460 V60 Hz0.37 kWWith PTC, speed control range 1:5

* Three-phase motor according to IEC 60034-1

Motor data sheets can be requested for more information. Versions 265/460V – 60Hz, special motors or special motor flanges are available on request.

Information for use in areas at risk from explosion

Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.

Hydraulic Diaphragm Metering Pump HYDRO HA2a

Technical data for HYDRO HA2a 50 Hz

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
60125150187214
mmbarl/hl/hl/hl/hl/hml/strokem WCG-DNkg
* Double ball valve with female thread
16100[3.0][6.5](8.5) – 8.5(10) – 11(12) – 133.03.0Rp 1/4 – DN 6 *31
1664[4.0](10) – 10(10) – 13(12) – 16.5(14) – 18.53.03.0Rp 1/4 – DN 6 *31
1640[5.5](10) – 13(12) – 15.5(14) – 19.5(16) – 23.53.03.0Rp 1/4 – DN 6 *31
1625[6.5](12) – 14.5(14) – 17.5(17) – 22.5(20) – 26.53.03.0Rp 1/4 – DN 6 *31
1610(7) – 7.5(13) – 16.5(15) – 19.5(18) – 24.5(22) – 29.53.03.0Rp 1/4 – DN 6 *31
1864[6.5](12) – 15.5(18.5) – 18.5(24.5) – 24.5(26) – 26.53.83.0G 3/4 – DN 1031
1840(7) – 8(13) – 18.5(22) – 22(26) – 28.5(26) – 32.53.83.0G 3/4 – DN 1031
1825(8) – 9(16) – 19.5(23) – 24.5(26) – 30.5(28) – 35.53.83.0G 3/4 – DN 1031
1810(8) – 10(16) – 21.5(23) – 26.5(29) – 33.5(28) – 37.53.83.0G 3/4 – DN 1031
2240(7) – 7.5(20) – 25.5(27) – 28.5(37) – 42.5(44) – 485.73.0G 3/4 – DN 1031
2225(7) – 8.5(20) – 25.5(25) – 33.5(35) – 43.5(40) – 515.73.0G 3/4 – DN 1031
2210(8) – 10(17) – 28.5(25) – 36.5(30) – 47(40) – 545.73.0G 3/4 – DN 1031
2625(20) – 22(35) – 49(40) – 59(65) – 72(50) – 837.93.0G 3/4 – DN 1031
2610(20) – 23.5(30) – 51(35) – 61(40) – 76(45) – 867.93.0G 3/4 – DN 1031

Technical data for HYDRO HA2a 60 Hz

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
72149180224
mmbarl/hl/hl/hl/hml/strokem WCG-DNkg
* Double ball valve with female thread
16100[3.5][7.5](10) – 10(12) – 133.03.0Rp 1/4 – DN 6 *31
1664[4.5](10) – 11.5(12) – 15.5(14.5) – 19.53.03.0Rp 1/4 – DN 6 *31
1640[6.5](12) – 15.5(14.5) – 18.5(16.5) – 233.03.0Rp 1/4 – DN 6 *31
1625[7.5](14.5) – 17(16.5) – 21(20.5) – 273.03.0Rp 1/4 – DN 6 *31
1610(8.5) – 9(15.5) – 19.5(18) – 23(21.5) – 293.03.0Rp 1/4 – DN 6 *31
1864[7.5](14.5) – 18.5(22) – 22(29) – 293.83.0G 3/4 – DN 1031
1840(8.5) – 9.5(15.5) – 22(26) – 26(31) – 343.83.0G 3/4 – DN 1031
1825(9.5) – 10.5(19.5) – 23(27.5) – 29(31) – 36.53.83.0G 3/4 – DN 1031
1810(9.5) – 12(19.5) – 25.5(27.5) – 31.5(34.5) – 403.83.0G 3/4 – DN 1031
2240(8.5) – 9(24) – 30(32.5) – 34(44) – 50.55.73.0G 3/4 – DN 1031
2225(8.5) – 10(24) – 30(30) – 40(42) – 525.73.0G 3/4 – DN 1031
2210(9.5) – 12(20) – 34(36) – 43(44) – 50.55.73.0G 3/4 – DN 1031
2625(24) – 26(42) – 58(48) – 70.5(78) – 867.93.0G 3/4 – DN 1031
2610(24) – 28(36) – 60.5(42) – 73(48) – 917.93.0G 3/4 – DN 1031

The permitted rated flow configuration is possible in the stated range when pumps are selected in accordance with API 675 (control range 1:10).

The litre capacity indicated using […] is the maximum litre capacity with an applicable control range of 1:5 and does not therefore satisfy API 675.

Example: with 16 mm piston, pressure 25 bar and stroke rate of 150 strokes/min gives (14) – 17.5, i.e. the control range of 1:10 is met for a rated flow of between 14 l/h and 17.5 l/h.

PVDF version max. 25 bar, PTFE + 25 % carbon; PTFE up to 16 bar

Wetted materials for HYDRO HA2a

Identity code of materialDosing headConnection on suction/discharge sideSeals/ball seatBalls
P1PVDFPVDFPTFE/PTFE + 25 % carbonCeramic
S1Stainless steel 1.4571/1.4404Stainless steel 1.4581PTFE/stainless steel 1.4404Ceramic
T1PTFE + 25% carbonPVDFPTFE/PTFE + 25 % carbonCeramic

Motor data for HYDRO HA2a

Identity code specificationPower supplyRemarks
S3-phase, IP 55*230 V/400 V50 Hz0.37 kW
T3-phase, IP 55*230 V/400 V
265 V/460 V
50 Hz
60 Hz
0.37 kWWith PTC, speed control range 1:5
R3-phase, IP 55*230 V/400 V50 Hz0.45 kWWith PTC, speed control range 1:20, with external fan 1-phase 230 V; 50/60 Hz
V1-phase, IP 55*230 V50 Hz0.37 kWVariable speed stroke control motor with integrated frequency converter
L3-phase, II 2G Ex de IIC T4 Gb230 V/400 V50 Hz0.37 kWWith PTC, speed control range 1:5
Q3-phase, II 2G Ex de IIC T4265 V/460 V60 Hz0.37 kWWith PTC, speed control range 1:5

* 3-phase AC motor in accordance with IEC 60034-1

Motor data sheets can be requested for more information. 265/460V – 60Hz versions, special motors or special motor flanges are available on request.

Information for use in areas at risk from explosion

Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.

Hydraulic Diaphragm Metering Pump HYDRO HA3a

Technical data for HYDRO HA3a 50 Hz

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
60125150187214
mmbarl/hl/hl/hl/hl/hml/strokem WCG-DNkg
* Double ball valve with female thread
22100[9.0][19.0][25.0][30.5][32.0]5.73.0Rp 3/8 – DN 8 *41
2264[11.0][26.0][31.5][40.0][46.0]5.73.0Rp 3/8 – DN 8 *41
2240[12.0][28.5][35.5][45.0][51.5]5.73.0Rp 3/8 – DN 8 *41
2225[12.5][30.5][37.0][47.0][55.0]5.73.0Rp 3/8 – DN 8 *41
2210[13.5][31.5][39.0][50.0][57.5]5.73.0Rp 3/8 – DN 8 *41
2664(18) – 19(35) – 43.5(40) – 51.5(55) – 63(65) – 737.93.0G 3/4 – DN 1041
2640(18) – 21(37) – 45.5(40) – 55(50) – 71(70) – 817.93.0G 3/4 – DN 1041
2625(15) – 21(30) – 49.5(40) – 59(55) – 74(70) – 847.93.0G 3/4 – DN 1041
2610(15) – 22(30) – 49.5(35) – 61(50) – 77(80) – 877.93.0G 3/4 – DN 1041
3240(25) – 25.5(50) – 66(70) – 80(65) – 101.5(70) – 116.512.03.0G 1 – DN 1541
3225(25) – 26.5(50) – 69(65) – 83(65) – 105.5(70) – 122.512.03.0G 1 – DN 1541
3210(22) – 31.5(50) – 74(70) – 90(60) – 112.5(65) – 12912.03.0G 1 – DN 1541
3825(25) – 50.5(70) – 110.5(80) – 126(150) – 166(180) – 18717.03.0G 1 – DN 1541
3810(30) – 51.5(80) – 111.5(90) – 135(150) – 168(180) – 19117.03.0G 1 – DN 1541

Technical data for HYDRO HA3a 60 Hz

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
72149180224
mmbarl/hl/hl/hl/hml/strokem WCG-DNkg
* Double ball valve with female thread
22100[10.0][22.0][29.5][36.5]5.73.0Rp 3/8 – DN 8 *41
2264[13.0][30.5][38.0][47.5]5.73.0Rp 3/8 – DN 8 *41
2240[14.5][34.0][42.5][53.5]5.73.0Rp 3/8 – DN 8 *41
2225[15.0][36.5][44.5][56.0]5.73.0Rp 3/8 – DN 8 *41
2210[16.0][37.5][47.0][59.5]5.73.0Rp 3/8 – DN 8 *41
2664(21.5) – 22.5(42) – 51.5(48) – 61.5(66) – 757.93.0G 3/4 – DN 1041
2640(21.5) – 25(44) – 54(48) – 66(60) – 857.93.0G 3/4 – DN 1041
2625(18) – 25(36) – 59(48) – 70.5(66) – 88.57.93.0G 3/4 – DN 1041
2610(18) – 26(36) – 59(42) – 73(60) – 927.93.0G 3/4 – DN 1041
3240(30) – 30.5(60) – 78.5(84) – 96(78) – 12112.03.0G 1 – DN 1541
3225(30) – 31.5(60) – 82(78) – 99.5(78) – 12612.03.0G 1 – DN 1541
3210(26.5) – 37.5(60) – 88(84) – 108(72) – 134.512.03.0G 1 – DN 1541
3825(30) – 60.5(84) – 131(96) – 151(180) – 19817.03.0G 1 – DN 1541
3810(36) – 61.5(96) – 132(108) – 162(180) – 20117.03.0G 1 – DN 1541

The permitted rated flow configuration is possible in the stated range when pumps are selected in accordance with API 675 (control range 1:10).

The litre capacity indicated using […] is the maximum litre capacity with an applicable control range of 1:5 and does not therefore satisfy API 675.

Example: a 26 mm piston, 25 bar pressure and stroke rate of 150 strokes/min results in (40) – 59, i.e. the control range of 1:10 is met for a rated flow of between 40 l/h and 59 l/h.

PVDF version max. 25 bar, PTFE + 25 % carbon; PTFE up to 16 bar

Wetted materials for HYDRO HA3a

Identity code of materialDosing headConnection on suction/discharge sideSeals/ball seatBalls
P1PVDFPVDFPTFE/PTFE + 25 % carbonCeramic
S1Stainless steel 1.4571/1.4404Stainless steel 1.4581PTFE/ZrO2 (DN 15/DN20 stainless steel 1.4404)Ceramic
T1PTFE + 25% carbonPVDFPTFE/PTFE + 25 % carbonCeramic

Motor data for HYDRO HA3a

Identity code specificationPower supplyRemarks
S3-phase, IP 55*230 V/400 V50 Hz0.75 kW
T3-phase, IP 55*230 V/400 V
265 V/460 V
50 Hz
60 Hz
0.75 kWWith PTC, speed control range 1:5
R3-phase, IP 55*230 V/400 V50 Hz0.75 kWWith PTC, speed control range 1:20, with external fan 1-phase 230 V; 50/60 Hz
V1-phase, IP 55*230 V50 Hz0.75 kWVariable speed stroke control motor with integrated frequency converter
L3-phase, II 2G Ex de IIC T4230 V/400 V50 Hz0.75 kWWith PTC, speed control range 1:5
Q3-phase, II 2G Ex de IIC T4265 V/460 V60 Hz0.75 kWWith PTC, speed control range 1:5

* 3-phase AC motor in accordance with IEC 60034-1

Motor data sheets can be requested for more information. 265/460V – 60Hz versions, special motors or special motor flanges are available on request.

Information for use in areas at risk from explosion

Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.

Hydraulic Diaphragm Metering Pump HYDRO HA4a

Technical data for HYDRO HA4a 50 Hz

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
71103136188214
mmbarl/hl/hl/hl/hl/hml/strokem WCG-DNkg
4040[79][118](150) – 154(200) – 211(220) – 24225.13G 1 1/2 – DN 2569
4025[80][121](150) – 160(200) – 219(220) – 25025.13G 1 1/2 – DN 2569
4016[82][125][162](200) – 225(220) – 25425.13G 1 1/2 – DN 2569
4010[83](100) – 125(150) – 166(200) – 228(220) – 25625.13G 1 1/2 – DN 2569
407[84](100) – 127(150) – 167(200) – 230(220) – 26125.13G 1 1/2 – DN 2569
5225[142](200) – 204(200) – 271(370) – 372[425]42.43G 1 1/2 – DN 2569
5216[143](190) – 205(200) – 274(370) – 376[425]42.43G 1 1/2 – DN 2569
5210[144](180) – 207(200) – 276(370) – 379[426]42.43G 1 1/2 – DN 2569
527[145](180) – 209(200) – 277[380][426]42.43G 1 1/2 – DN 2569
6316(200) – 212(280) – 306(390) – 401[562][635]62.33G 1 1/2 – DN 2576
6310(210) – 215(280) – 311(380) – 407[562][638]62.33G 1 1/2 – DN 2576
637(210) – 216(280) – 312(370) – 408[564][648]62.33G 1 1/2 – DN 2576
8010(280) – 350(420) – 509(580) – 657(890) – 914(1,050) – 1,056100.43G 2 – DN 3287
807(270) – 352(420) – 513(590) – 683(890) – 947(1,050) – 1,080100.43G 2 – DN 3287
947(350) – 493(500) – 710(820) – 936(1,000) – 1,258(1,400) – 1,440138.73G 2 1/4 – DN 4096

Technical data for HYDRO HA4a 60 Hz

Plunger ØMax. pressureMax. pump capacity in l/h at strokes/minTheor. stroke volumeSuction liftConnection on suction/discharge sideShipping weight
86124164225
mmbarl/hl/hl/hl/hml/strokem WCG-DNkg
4040[95][142](180) – 200(240) – 25225.13G 1 1/2 – DN 2569
4025[96][145](180) – 185(240) – 26225.13G 1 1/2 – DN 2569
4016[99][150][195](240) – 26925.13G 1 1/2 – DN 2569
4010[100](120) – 150(180) – 200(240) – 27225.13G 1 1/2 – DN 2569
407[101](120) – 152(180) – 201(240) – 27525.13G 1 1/2 – DN 2569
5225[171](240) – 245(240) – 327(440) – 44542.43G 1 1/2 – DN 2569
5216[172](230) – 246(240) – 330(450) – 45042.43G 1 1/2 – DN 2569
5210[174](220) – 249(240) – 333(450) – 45542.43G 1 1/2 – DN 2569
527[176](220) – 251(240) – 334[454]42.43G 1 1/2 – DN 2569
6316(245) – 256(340) – 368(470) – 483[672]62.33G 1 1/2 – DN 2576
6310(255) – 260(340) – 374(460) – 490[672]62.33G 1 1/2 – DN 2576
637(260) – 262(340) – 375(445) – 491[674]62.33G 1 1/2 – DN 2576
8010(340) – 424(505) – 613(700) – 792(1,065) – 1,094100.43G 2 – DN 3287
807(330) – 426(505) – 618(711) – 823(1,065) – 1,133100.43G 2 – DN 3287
947(430) – 597(600) – 854(990) – 1,128(1,200) – 1,506138.73G 2 1/4 – DN 4096

The permitted rated flow configuration is possible in the stated range when pumps are selected in accordance with API 675 (control range 1:10).

The litre capacity indicated using […] is the maximum litre capacity with an applicable control range of 1:5 and does not therefore satisfy API 675.

Example: with 52 mm piston, 10 bar pressure and stroke rate of 136 strokes/min results in (200) – 276, i.e. the control range of 1:10 is met for a rated flow of between 200 l/h and 276 l/h.

PVDF version max. 25 bar, PTFE + 25 % carbon; PTFE up to 10 bar

Wetted materials for HYDRO HA4a

Identity code of materialDosing headConnection on suction/discharge sideSealsValve seatsValve balls up to DN 25Valve plates/valve springs
P1PVDFPVDFPTFEPTFE + 25% carbonGlassCeramic/E-CTFE
S1Stainless steel 1.4404Stainless steel 1.4404PTFEPTFEStainless steel 1.4401Stainless steel 1.4404/Hastelloy C
T1PTFE + 25% carbonPVDFPTFEPTFE + 25% carbonGlassCeramic/E-CTFE
V1PVCPVDFPTFEPTFEGlassCeramic/E-CTFE
Y1PPTPVDFPTFEPTFEGlassCeramic/E-CTFE

Motor data for HYDRO HA4a

Identity code specificationPower supplyRemarks
S3-phase, IP 55*230 V/400 V50 Hz1.1 kW
T3-phase, IP 55*230 V/400 V
265 V/460 V
50 Hz
60 Hz
1.1 kWWith PTC, speed control range 1:5
R3-phase, IP 55*230 V/400 V50 Hz1.5 kWWith PTC, speed control range 1:20, with external fan 1-phase 230 V; 50/60 Hz
V3-phase, IP 55*400 V50 Hz1.5 kWVariable speed stroke control motor with integrated frequency converter
L3-phase, II 2G Ex de IIC T4 Gb230 V/400 V50 Hz1.1 kWWith PTC, speed control range 1:5
Q3-phase, II 2G Ex de IIC T4265 V/460 V60 Hz1.1 kWWith PTC, speed control range 1:5

* 3-phase AC motor in accordance with IEC 60034-1

Motor data sheets can be requested for more information. 265/460V – 60Hz versions, special motors or special motor flanges are available on request.

Information for use in areas at risk from explosion

Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.

Available, you can order now!
Unavailable!